Central air-conditioning fan coil thermostat, three-speed switch manufacturers

by:Edison      2020-08-20

central air-conditioning fan coil thermostat manufacturer three-speed switch manufacturer production central air conditioning LCD thermostat switch panel, all sales thermostat panel logo can be printed. Quantity is with preferential treatment. All the thermostat switch panel system three years warranty, lifelong free maintenance YORK LCD thermostat YORK central air conditioning panel three-speed switch air conditioning fan coil units with adjustable thermostat

electric heating cable floor heating is a line a thermostat. Also a central air conditioning is a heating area special switch panel LCD thermostat fan coil. Customers in the use of electrical heating floor, because floor heating is temperature control system, a lot of customers in the use of floor heating, with temperature control system to achieve the energy saving effect of heating system, but in the use of misunderstanding between the following points:

error one, it is on or off more energy-efficient central air-conditioning fan coil thermostat manufacturer three-speed switch manufacturers

some customers in order to save electricity, often when someone to open the thermostat, don't have to shut down the thermostat, when I was in fact the wrong. Electricity floor heating system is running a low temperature, due to the general heating cable is laid in concrete, concrete need to heating to keep them warm. So the heating cable floor radiant heating system has good heat resistance, in this case the use effect of floor heating system with hysteresis. That is to say, after the open system need some time to make the room temperature reaches set temperature, the indoor temperature after shut down the system won't fell rapidly, take a long time to reduce temperature. Such not only less than the energy saving effect of floor heating system, but also increase the operating cost of heating system, at the same time, frequent open or close the heating system will reduce the service life of floor heating system.

the right approach: central air-conditioning fan coil thermostat manufacturer three-speed switch manufacturers

not commonly used room can put the temperature down a few degrees, in a long time when you leave the room just put the thermostat down a few degrees temperature, leave in a long time not to live or for a long time can choose relationship under the condition of system, but it's important to note that if you have any equipment or piping afraid of freezing room, open or want to watch frosty temperature to prevent the equipment or pipeline.

error (2) set high temperature warming faster

some users feel the room temperature is low, need to set the temperature of the thermostat to rapid heating up, this approach is also wrong. Room temperature rise time depends on the indoor and outdoor temperature difference and the installation of power per unit area of the room. Under the condition of the installation power and a certain temperature difference between indoor and outdoor, no matter how many degrees, you set it to room temperature to you need time is the same, if your room is now 16 ℃, you want to let the room temperature 18 ℃, in this case you set up 18 ℃ and you set up 20 ℃ and 25 ℃ temperature 18 ℃ to time is the same.

the right approach: central air-conditioning fan coil thermostat manufacturer three-speed switch manufacturers

how much is set how many degrees, or adopt the intelligent temperature controller, central air conditioning LCD thermostat fan coil units dedicated switch panel can automatically calculate the hvac thermostat opened ahead of time.

error three, all temperature

many users in setting temperature, room temperature required for setting according to oneself, but after the temperature setting is good but not set heating effect. Actually the thermostat according to the detection methods are divided into ground temperature, room temperature and double temperature. Ground temperature thermostat is to detect the ground temperature to control the ground temperature; Room temperature thermostat is to detect the indoor air temperature to control indoor temperature; Double temperature thermostat is in control of ground temperature down control of indoor temperature, the average surface temperature can not be adjusted, but some good thermostat can set the temperature of the ground temperature. In appearance the thermostat difference is not big, easy to cause misunderstanding. Ground temperature and room temperature is different, at the time of setting temperature to distinguish between ground temperature thermostat and room temperature hvac thermostat, general geothermal temperature setting of the thermostat is higher than that of room temperature thermostat setting temperature, if the ground temperature thermostat according to room temperature thermostat to set the room is not hot.

the right approach: central air-conditioning fan coil thermostat manufacturer three-speed switch manufacturers

in setting temperature to determine the type of the thermostat, according to the different types of thermostat set different temperature. Temperature control system is the key to the floor heating system energy conservation operation, no matter what the nature of the floor heating system, when use shall comply with the relevant specification, do not affect the floor heating system due to incorrect use of the heating effect.

1, the automatic mode, automatic mode switch of the fan and fan speed by the current indoor temperature and set temperature difference in temperature. For example when indoor temperature and set temperature when the temperature difference is bigger, the thermostat will start on the heating ( Or refrigeration) Equipment using large wind speed at the same time to speed up the heat transfer between air and equipment, to make heat ( Or cold quantity) As soon as possible by into indoor; When indoor temperature very close to the set temperature, the system does not to the indoor cooling ( Or hot) , the fan will stop running.

2, manual mode, the operation of the fan is locked for normally open rather than determined by the size of the set temperature and indoor temperature. Fan speed control by the user through the slide switches or set the system menu to decide.


The , essentially perfected by hvac expansion valve, is one of the first home appliance to be widely distributed.
More about the most suitable , visit Edison HVAC Valves to get your offer!
We focus on operational procedure and manufacturing facilities of home thermostat.
Turn to Zhuhai Edison Smart Home Co., Ltd. if you are looking for premier ac compressor control valve solution, affordable packages, and quality wireless thermostat products! We produce wide series of high quality, first-class , and provide professional heat pump thermostat services at great prices.
This is especially true when Zhuhai Edison Smart Home Co., Ltd. have got a global business that's building bridges between manufacturers and customers across the globe.

Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...
Thank you so much for your enquiry. We will get back to you ASAP